Honeywell

Honeywell Sensepoint Flammable and Toxic Sensors

Complete the form below and a member of our team will be in touch shortly to discuss your requirments.

LOOKING FOR SPECIALIST GAS DETECTION SOLUTIONS

Visit our sister site for full service and support

The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a high quality, low cost solution to their industrial gas monitoring needs. Installation inpotentially explosive atmospheres is made by the use of a suitable Exd or Exe approved junction box. The industry standard outputs from Sensepoint are connected to either a choice of Honeywell Analytics’ controllers or 3rd party DCS/PLC systems. Both flammable and toxic versions are certified to the latest European ATEX safety and performance standards.

The flammable detector is available in either %LEL or PPM detection range versionsand provides an industry standard mV bridge output. Typical life expectancy is greater than 5 years, after which the detector is simply replaced with a new one. The toxic detectors are supplied pre calibrated for easy installation and provide an industry standard 2 wire 4-20mA loop output. User connections are Exd, while front end Intrinsic Safety (IS) design allows for easy exchange of the replaceable sensor
while powered. IS design also removes the need for a sinter enabling very fast speed
of response and detection of ‘sticky’ gases such as Chlorine and Ammonia.

The Sensepoint high temperature sensor has been specifically designed for the detection of combustible gases in high temperature hazardous area locations. Typical applications include turbine enclosures and drying ovens used in solvent based printing and coating machines. These applications require a sensor that provides reliable and stable detection allowing low level alarm settings across a wide temperature range.

Utilizing a specially matched pair of Sieger poison resistant combustible gas detection elements, the Sensepoint High Temperature Sensor has a very stable baseline allowing alarm trip points to be set as low as 5% LEL across a temperature range of -55°C to +150°C (-67°F to +302°F). The gas measuring range can be configured from 0-20% LEL up to 0-100% LEL depending on the type of
controller used.

Sensepoint has proven its suitability across a wide range of demanding applications
by delivering high performance and reliability at an affordable cost

 Configurations Available

Sensepoint Flammable (0-100%LEL +80°C, 0-10%LEL +65°C)    
       
2106B1200 Sensepoint 0-100% LEL Flam. Sensor M20    
2106B1201 Sensepoint 0-100% LEL Flam. Sensor M25    
2106B1202 Sensepoint 0-100% LEL Flam. Sensor M26    
2106B1203 Sensepoint Flammable M26 VQ1AB pellistor    
2106B1204 Sensepoint 0-100% LEL Flam. Sensor 3/4NPT    
2106B1205 Sensepoint ppm Flam. Sensor M20*    
2106B1206 Sensepoint ppm Flam. Sensor M25*    
2106B1209 Sensepoint ppm Flam. Sensor 3/4NPT*    
       
* please refer to the manual for gas specific unit and range    
Note: For a complete sensor order correct number of BARTEC J.Box 00780-A-0100 and Weather Housing 02000-A-1640 
       
Sensepoint Flammable - High Temperature (150°C with 3rd party performance approval)    
       
2106B2310 Sensepoint HT Flammable Sensor (ATEX) M20    
2106B2311 Sensepoint HT Flammable Sensor (ATEX) M25    
2106B2312 Sensepoint HT Flammable Sensor (ATEX) 3/4 NPT    
       
Note: For a complete sensor order correct number of FEEL Exe J.Box 2052D0001 and Weather Housing 00780-A-0076
       
Sensepoint Toxic     
       
2106B1400 Sensepoint H2S 0-20 ppm Toxic Sensor M20    
2106B1401 Sensepoint H2S 0-50 ppm Toxic Sensor M20    
2106B1402 Sensepoint H2S 0-100 ppm Toxic Sensor M20    
2106B1500  Sensepoint H2S 0-20 ppm Toxic Sensor M25    
2106B1501    Sensepoint H2S 0-50 ppm Toxic Sensor M25    
2106B1502 Sensepoint H2S 0-100 ppm Toxic Sensor M25    
2106B1700 Sensepoint H2S 0-20 ppm Toxic Sensor 3/4NPT    
2106B1701 Sensepoint H2S 0-50 ppm Toxic Sensor 3/4NPT    
2106B1702 Sensepoint H2S 0-100 ppm Toxic Sensor 3/4NPT    
2106B1800 Sensepoint H2S 0-20 ppm Toxic Sensor 3/4NPT CSA    
2106B1801 Sensepoint H2S 0-50 ppm Toxic Sensor 3/4NPT CSA    
2106B1802 Sensepoint H2S 0-100 ppm Toxic Sensor 3/4NPT CSA    
2106B1405 Sensepoint CO 0-100 ppm Toxic Sensor M20    
2106B1406 Sensepoint CO 0-200 ppm Toxic Sensor M20    
2106B1407 Sensepoint CO 0-500 ppm Toxic Sensor M20    
2106B1505     Sensepoint CO 0-100 ppm Toxic Sensor M25    
2106B1506      Sensepoint CO 0-200 ppm Toxic Sensor M25    
2106B1507       Sensepoint CO 0-500 ppm Toxic Sensor M25    
2106B1705 Sensepoint CO 0-100 ppm Toxic Sensor 3/4NPT    
2106B1706 Sensepoint CO 0-200 ppm Toxic Sensor 3/4NPT    
2106B1707 Sensepoint CO 0-500 ppm Toxic Sensor 3/4NPT    
2106B1805 Sensepoint CO 0-100 ppm Toxic Sensor 3/4NPT CSA    
2106B1806 Sensepoint CO 0-200 ppm Toxic Sensor 3/4NPT CSA    
2106B1807 Sensepoint CO 0-500 ppm Toxic Sensor 3/4NPT CSA    
2106B1410 Sensepoint Cl2 0-5 ppm Toxic Sensor M20    
2106B1411 Sensepoint Cl2 0-15 ppm Toxic Sensor M20    
2106B1510       Sensepoint Cl2 0-5 ppm Toxic Sensor M25    
2106B1511       Sensepoint Cl2 0-15 ppm Toxic Sensor M25    
2106B1711 Sensepoint Cl2 0-15 ppm Toxic Sensor 3/4NPT    
2106B1810 Sensepoint Cl2 0-5 ppm Toxic Sensor 3/4NPT CSA    
2106B1811 Sensepoint Cl2 0-15 ppm Toxic Sensor 3/4NPT CSA    
2106B1413 Sensepoint NH3 0-50 ppm Toxic Sensor M20    
2106B1414 Sensepoint NH3 0-1000 ppm Toxic Sensor M20    
2106B1415 Sensepoint NH3 0-100 ppm Toxic Sensor M20    
2106B1513          Sensepoint NH3 0-50 ppm Toxic Sensor M25    
2106B1514           Sensepoint NH3 0-1000 ppm Toxic Sensor M25    
2106B1515          Sensepoint NH3 0-100 ppm Toxic Sensor M25    
2106B1713 Sensepoint NH3 0-50 ppm Toxic Sensor 3/4NPT    
2106B1714 Sensepoint NH3 0-1000 ppm Toxic Sensor 3/4NPT    
2106B1715 Sensepoint NH3 0-100 ppm Toxic Sensor 3/4NPT    
2106B1813 Sensepoint NH3 0-50 ppm Toxic Sensor 3/4NPT CSA    
2106B1814 Sensepoint NH3 0-1000 ppm Toxic Sensor 3/4NPT CSA    
2106B1815 Sensepoint NH3 0-100 ppm Toxic Sensor 3/4NPT CSA    
2106B1416 Sensepoint H2 0-1000 ppm Toxic Sensor M20    
2106B1417 Sensepoint H2 0-10000 ppm Toxic Sensor M20     
2106B1516         Sensepoint H2 0-1000 ppm Toxic Sensor M25    
2106B1517    Sensepoint H2 0-10000 ppm Toxic Sensor M25     
2106B1716 Sensepoint H2 0-1000 ppm Toxic Sensor 3/4NPT    
2106B1717 Sensepoint H2 0-10000 ppm Toxic Sensor 3/4NPT    
2106B1816 Sensepoint H2 0-1000 ppm Toxic Sensor 3/4NPT CSA    
2106B1817 Sensepoint H2 0-10000ppm Toxic Sensor 3/4NPT CSA    
2106B1418 Sensepoint NO 0-100 ppm Toxic Sensor M20     
2106B1518     Sensepoint NO 0-100 ppm Toxic Sensor M25     
2106B1718 Sensepoint NO 0-100 ppm Toxic Sensor 3/4NPT    
2106B1818 Sensepoint NO 0-100 ppm Toxic Sensor 3/4NPT CSA    
2106B1420 Sensepoint SO2 0-15 ppm Toxic Sensor M20    
2106B1421 Sensepoint SO2 0-50 ppm Toxic Sensor M20     
2106B1520     Sensepoint SO2 0-15 ppm Toxic Sensor M25    
2106B1521          Sensepoint SO2 0-50 ppm Toxic Sensor M25     
2106B1720 Sensepoint SO2 0-15 ppm Toxic Sensor 3/4NPT    
2106B1721 Sensepoint SO2 0-50 ppm Toxic Sensor 3/4NPT    
2106B1820 Sensepoint SO2 0-15 ppm Toxic Sensor 3/4NPT CSA    
2106B1821 Sensepoint SO2 0-50 ppm Toxic Sensor 3/4NPT CSA    
2106B1422 Sensepoint NO2 0-10 ppm Toxic Sensor M20    
2106B1522       Sensepoint NO2 0-10 ppm Toxic Sensor M25    
2106B1722 Sensepoint NO2 0-10 ppm Toxic Sensor 3/4NPT    
2106B1822 Sensepoint NO2 0-10 ppm Toxic Sensor 3/4NPT CSA    
2106B1430 Sensepoint O2 25% V/V Toxic Sensor M20    
2106B1530      Sensepoint O2 25% V/V Toxic Sensor M25    
2106B1730 Sensepoint O2 25% V/V Toxic Sensor 3/4NPT    
2106B1830 Sensepoint 0-25 V/V O2 Toxic Sensor 3/4NPT CSA    
       